HYDROSTATIC LEVEL MEASUREMENT[email protected]
≋SubmersibleLevelPROBES · CABLES · INTEGRATION
Menu

ORIGINAL MODEL → CONFIGURED COMPARISON

Submersible Level Transmitter Cross-Reference

Find original WIKA, KELLER, Endress+Hauser, VEGA, Dwyer, Druck and Siemens models, then send a configuration-specific replacement review.

ORIGINAL MODEL LOOKUP

Find the installed model and compare its functions.

16 original model references found. Select the exact record; search text never proves interchangeability.

WIKA

LH-10

High-performance submersible reference

Candidate enquiry path: REVIEW

Provide the exact legacy datasheet and installed nameplate. Do not infer lifecycle status or a successor from a similar model number.

Original model enquiry; lifecycle not asserted

Read the original maker reference ↗

Request review of LH-10 ↗

WIKA

LH-20

Submersible model reference in the original maker catalogue

Candidate enquiry path: REVIEW

Supply the full configured datasheet, output, materials, pressure reference and installation dimensions. No stock, lifecycle or interchangeability claim is inferred.

Read the original maker reference ↗

Request review of LH-20 ↗

COMPARISON METHOD

Match the installed function before comparing the part number.

The lookup identifies independent original model families and a starting path for an SLV enquiry. It does not prove a mechanical drop-in fit, identical signals, equal uncertainty or transferable certification. Third-party names are references only; no affiliation is claimed. Read the original maker document for the full configured code, then compare the proposed assembly against that record.

Original model cross-reference conceptual decision workflow; not a released hardware drawing or certified procedure
Original decision diagram. Evidence is required for the exact proposed assembly and project.
Comparison dimensionOriginal installation evidenceCandidate acceptance check
Pressure reference and datumVented gauge or absolute type; diaphragm elevation and tank/well referenceSame measurement basis or an explicitly reviewed compensation change; no headspace-pressure assumption
Span / density / uncertaintyPressure units, calibrated span, process SG and error definitionConfigured span and uncertainty at the required conditions; percent-FS and total-error-band terms are not interchangeable
Electrical functionsCurrent/voltage, HART, RS485 or SDI-12; temperature channels, supply and loadActual pinout, command/register map, channel units and complete input/loop test
Mechanical envelopeProbe diameter/length, process fittings and minimum measured casing clearanceApproved configured drawing and mounting; nominal pipe size is not clearance evidence
Cable and wet partsLength, route, reinforcement, jacket, diaphragm, seal compound and cleaningContinuous installed route and whole wet-material review, including terminations
Approval and recordsExact marking, certificate/model, control drawing and site requirementsAccepted supplied-equipment evidence and full circuit review; no copied certification

Three replacement requests that need different outcomes

WIKA LS-10 versus IL-10

LS-10 is a general application reference. IL-10 introduces intrinsic-safety and associated-apparatus requirements. Similar names and the same current output do not remove that distinction.

KELLER Microlevel in a narrow well

Check whether the installation uses current, digital level/temperature or both. The candidate needs measured casing clearance and the required functions; a slim analogue-only probe is not automatically equivalent.

Waterpilot FMX167 legacy enquiry

The original maker refers visitors to its newer-generation section. That supports reviewing lifecycle options; it does not establish a compatible SLV successor or current stock availability.

Accept a documented comparison, not an unverified interchange claim.

Attach the original nameplate, order code, datasheet and installation drawing. Identify every function currently used by the PLC or logger. Ask for a written differences list with the quotation, including any change to mounting, input scaling, vent termination, diagnostics or certificate scope.

If the application requires approval, obtain acceptance of the exact equipment and circuit before release. A standard SLV enquiry code must never be treated as the original certified model marking. Price, delivery, discontinuation and availability depend on the current configured quotation; this lookup does not publish unverified competitor prices or lead times.

Questions to resolve before the configured quotation

Is the listed SLV family a verified 1:1 replacement?

No. It is an enquiry starting path. Confirm dimensions, mounting, materials, pressure reference, span, functions, input wiring and approvals for the exact original and proposed configurations.

Why are some results Engineering selection review?

Original families can contain several material, output and approval variants. Until the installed configuration is identified, a precise candidate would be a guess.

Can the original safety barrier stay installed?

Only after the approved circuit and exact equipment parameters are reviewed. Similar two-wire outputs do not establish barrier or certificate compatibility.

What if the original model has been discontinued?

Send the full nameplate and archived datasheet. Check the original maker lifecycle notice and compare the actual installed functions; a discontinued designation alone does not identify an equivalent.

Can I reuse the original wire colours?

Use the candidate configured pinout and approved installation instructions. Do not infer function from colour across manufacturers.

What should purchasing receive before ordering?

A configured quotation, differences list, drawing, pinout and agreed calibration/material/approval evidence, plus explicit commercial and delivery terms.

RESOLVE THE MISSING SPECIFICATION

Check the liquid, compare the original, or define an OEM project.

Liquid & material compatibility →

Search liquid review paths, compare PUR, PE and FEP cable, and prepare a complete wetted-material request with temperature, seals and concentration.

Original model cross-reference →

Find original WIKA, KELLER, Endress+Hauser, VEGA, Dwyer, Druck and Siemens models, then send a configuration-specific replacement review.

OEM & private-label projects →

Prepare an OEM hydrostatic probe brief: custom span, density, continuous vented cable, electronics, marking, pilot acceptance and production documents.

RETURN TO THE ACTUAL APPLICATION

Compare the eight enquiry families.