01 / WATER & ATMOSPHERIC TANKS / SLV-420
316L Water & Tank Submersible Level Transmitters
Specify a submerged gauge-pressure probe for clean water, storage tanks and compatible fuel applications.
316L body · qualified silicon / ceramic cell

Clean water tanks, reservoirs and wells
Match liquid chemistry, actual head above the probe and the PLC input.
Use in atmospheric vessels. Headspace pressure in a sealed tank adds pressure that this single vented probe cannot distinguish from level.
Define the configuration before the quotation
- 4–20 mA two-wire loop, 0–10 V or RS485 Modbus: request the required configuration.
- 0.25% / 0.5% FS accuracy targets require the configured range, temperature and calibration definition.
- Fuel and diesel require cable, seals, wetted-material and hazardous-area review.
THREE INPUTS THAT MAKE THE REVIEW USEFUL
Bring the installation into the specification.
Liquid density, operating temperature and cleaning chemicals
Supply, loop load, input type and required calibration record
Reviewing an existing tank-level probe?
WIKA LS-10 / IL-10, Endress+Hauser Waterpilot FMX21, Gems and Dwyer PBLT2 / SBLT2 are independent comparison references. Supply the exact installed model and datasheet. Span, wiring, dimensions, materials and required approvals need separate review; there is no claimed affiliation, certification transfer or universal 1:1 interchangeability.
SPECIFY THE CONFIGURED ASSEMBLY
Range, materials and cable requirements for SLV-420.
| Selection item | Request / option | Release check |
|---|---|---|
| Liquid-head range | Request the actual span; common water/tank requests 1–200 m H₂O | Calibrated span and maximum submergence are quoted separately. |
| Density / accuracy | State actual SG; 0.25% or 0.5% FS target | Accuracy definition, temperature and calibrated range need configuration evidence. |
| Wetted construction | Request 316L body with qualified silicon / ceramic cell | A steel reference photograph is not proof of 316L, seal or cable grade. |
| Signal / supply | 4–20mA, voltage, HART or RS485 enquiry | Released pinout, supply and loop-load limit must match the chosen electronics. |
| Cable | PUR / PE; FEP upgrade by application | Length includes the installed route and service allowance. |
A stilling tube can reduce movement; its openings must allow the liquid level to equalize.
Set the lowest measured liquid level above the diaphragm datum; do not rest the probe in sediment.
Fuel requires actual blend, seals/cable compatibility and site area classification.
Selection brief, not an issued manufacturing drawing, serial calibration certificate or blanket product approval. Confirm the exact release documents with the quotation.
READ THE INSTALLATION BEFORE THE SIGNAL
Keep a dry atmospheric reference and a stable sensor datum.
A fixed probe reads the liquid column above its diaphragm. Cable length covers the physical route to a dry termination. Neither a pipe-size label nor an image establishes the assembly dimensions.
Download installation & loop-load worksheet ↓REFERENCE CONSTRUCTION & INSTALLATION DETAILS
Inspect the probe, cable and termination arrangement.







CONFIGURE YOUR PROBE & TERMINATION
One complete specification.
One clear quote request.
Set liquid head, density, signal and the installed cable route. The configuration code carries these choices into your engineering request.
This code requests a configuration; the written quotation defines released dimensions, materials, approvals and availability.
Include this configuration in my RFQ ↗START WITH YOUR INSTALLATION
Four operating environments, four different selection decisions.
Chemical dosing tanks →
Specify chemical submersible probes from concentration, temperature, complete wetted materials and actual liquid density.
Generator fuel tanks →
Define low-head diesel tank measurement with fuel blend, usable level, cable route, area classification and generator input.
Groundwater & telemetry →
Plan groundwater pressure span, deployment cable, surveyed datum and low-power logger integration for borehole networks.
Lift stations & CSO →
Select a wastewater hydrostatic probe around rags, grease, turbulence, cleaning access, vent protection and pump-control acceptance.
KEEP THE WHOLE LOOP IN VIEW
From probe selection to dry cable termination.
Before you specify SLV-420
Is this a released stock model?
SLV-420 identifies an enquiry configuration family. Ask for the exact configured datasheet, materials, drawing and calibration acceptance criteria before placing an order.
Can I order cable length independently from range?
Yes, specify both independently. Cable must cover the installed route and service allowance; measuring range covers liquid head above the probe. The quote confirms maximum immersion and cable load.
START WITH THE INSTALLATION
Liquid. Depth. Cable. Signal.
Send these four inputs to start a configuration review.