07 / LOW-POWER FIELD MONITORING / SLV-SDI

SDI-12 & Modbus Groundwater Telemetry Level Sensors

Define a hydrostatic level and temperature measurement for a battery or solar logger, with the actual protocol, sampling cycle and energy budget.

SDI-12 / RS485 options · level and temperature targets

Digital groundwater logger integration concept; not a released assembly
Original engineering concept. Final dimensions and construction are defined by the configured drawing.

Groundwater networks, remote wells and solar telemetry

Choose the logger interface and measure the whole duty cycle.

SDI-12 and RS485 Modbus require different electrical interfaces and software. A digital output does not by itself establish low consumption, battery life or telemetry connectivity.

Define the configuration before the quotation

  • Request 3.5–200 m head spans, level plus temperature and the exact SDI-12 commands or Modbus register map.
  • Supply voltage, sleep current, active current, warm-up and sample time need model-specific evidence; no universal 3.3 V compatibility is assumed.
  • For SGMA-related projects, define the monitoring plan, datum, records and agency requirements; a probe alone does not establish compliance.

THREE INPUTS THAT MAKE THE REVIEW USEFUL

Bring the installation into the specification.

01

Logger make/model, interface, supply and firmware

02

Sample interval, warm-up time and power budget

03

Casing clearance, sensor datum and installation depth

SPECIFY THE CONFIGURED ASSEMBLY

Range, materials and cable requirements for SLV-SDI.

Selection itemRequest / optionRelease check
Span and channelsRequest 3.5–200 m head plus temperatureConfirm pressure reference, accuracy basis, channel order and units.
ProtocolSDI-12 or RS485 Modbus as separate configurationsRequire supported commands / registers, address, baud/parity and logger compatibility.
EnergyRequest sleep/active current, warm-up and measurement durationUse actual supply voltage and complete measurement cycle; no battery-life guarantee.
InstallationCasing ID, datum, deployment, surface route and service loopLiquid-head span does not size the cable or qualify maximum submergence.
Data qualityManual reference readings, timestamp and acceptance planSGMA or other monitoring obligations belong to the site program, not a product badge.

Keep the atmospheric vent dry; a low-power logger does not correct a blocked reference tube.

Long SDI-12 cables require topology, capacitance, voltage-drop and logger testing; the standard allows longer runs with fewer sensors. Include the full cycle in energy budgets.

Request a logger integration test and a recorded reference water-level check before network deployment.

Selection brief, not an issued manufacturing drawing, serial calibration certificate or blanket product approval. Confirm the exact release documents with the quotation.

INDEPENDENT TECHNICAL REFERENCES

Read the reference alongside its limits.

The SDI-12 Support Group defines the interface and protocol. STS provides an independent example of a level/temperature implementation. Neither reference establishes our supply limits, measured current, command set or battery life.

Third-party names identify independent sources. No affiliation, supplied-equipment approval or performance equivalence is claimed. Reviewed 17 November 2026.

READ THE INSTALLATION BEFORE THE SIGNAL

Keep a dry atmospheric reference and a stable sensor datum.

A fixed probe reads the liquid column above its diaphragm. Cable length covers the physical route to a dry termination. Neither a pipe-size label nor an image establishes the assembly dimensions.

Download installation & loop-load worksheet ↓
Digital groundwater logger and dry vent concept, not a two-wire current loop
Original installation concept. Two-wire loop example; digital interfaces and approved barrier circuits require their own drawings. Verify wiring, load and installation details against the configured assembly.

CONFIGURE YOUR PROBE & TERMINATION

One complete specification.
One clear quote request.

Set liquid head, density, signal and the installed cable route. The configuration code carries these choices into your engineering request.

ENQUIRY CONFIGURATION CODEComplete the measuring range
Indicative allowance per probe kit$174Probe, freight and tax excluded. Length prices apply to a matched base assembly; no generic first-5m FEP upgrade is free.

This code requests a configuration; the written quotation defines released dimensions, materials, approvals and availability.

Include this configuration in my RFQ ↗
Engineering accessories — indicative per probe kit

Bellows and desiccant options need a compatible compensation/vent design. Surge ratings, clamp load and controller functions are confirmed for the selected assembly.

START WITH YOUR INSTALLATION

Four operating environments, four different selection decisions.

Chemical dosing tanks →

Specify chemical submersible probes from concentration, temperature, complete wetted materials and actual liquid density.

Generator fuel tanks →

Define low-head diesel tank measurement with fuel blend, usable level, cable route, area classification and generator input.

Groundwater & telemetry →

Plan groundwater pressure span, deployment cable, surveyed datum and low-power logger integration for borehole networks.

Lift stations & CSO →

Select a wastewater hydrostatic probe around rags, grease, turbulence, cleaning access, vent protection and pump-control acceptance.

KEEP THE WHOLE LOOP IN VIEW

From probe selection to dry cable termination.

Before you specify SLV-SDI

Is this a released stock model?

SLV-SDI identifies an enquiry configuration family. Ask for the exact configured datasheet, materials, drawing and calibration acceptance criteria before placing an order.

Can I order cable length independently from range?

Yes, specify both independently. Cable must cover the installed route and service allowance; measuring range covers liquid head above the probe. The quote confirms maximum immersion and cable load.

START WITH THE INSTALLATION

Liquid. Depth. Cable. Signal.

Send these four inputs to start a configuration review.

Request an engineering quote ↗