HYDROSTATIC LEVEL MEASUREMENT[email protected]
≋SubmersibleLevelPROBES · CABLES · INTEGRATION
Menu

06 / FUEL & CLASSIFIED LOCATIONS / SLV-EX

Intrinsically Safe Diesel & Fuel Level Transmitter Selection

Build an engineering request for atmospheric fuel tanks and classified leachate duties around the exact site classification, certificate scope and complete loop.

Two-wire 4–20 mA target · certificate and barrier review

Complete intrinsic-safety circuit review concept; not a released assembly
Original engineering concept. Final dimensions and construction are defined by the configured drawing.

Generator fuel tanks, diesel storage and classified leachate

Select the approved circuit before releasing the probe.

SLV-EX is an enquiry family, not a certified model designation. Do not install in a classified location until the exact supplied equipment and installation documents have been accepted for that site.

Define the configuration before the quotation

  • Request 0.5–100 m liquid-head spans; define actual diesel, HVO, biodiesel or leachate composition.
  • ATEX, IECEx and North American requirements are separate evidence paths. Supply the exact required marking and jurisdiction.
  • Review certificate holder, full model designation, special conditions, barrier entity parameters, cable capacitance/inductance and control drawing.

THREE INPUTS THAT MAKE THE REVIEW USEFUL

Bring the installation into the specification.

01

Country, area classification, gas group and temperature class

02

Exact fuel blend, temperature, cable and seals

03

Approved barrier, supply, input load and control drawing

SPECIFY THE CONFIGURED ASSEMBLY

Range, materials and cable requirements for SLV-EX.

Selection itemRequest / optionRelease check
Application and spanFuel blend / leachate chemistry; request 0.5–100 mPressure span follows actual liquid head and density.
Required approvalJurisdiction, zone/division, gas group, temperature class and ambientObtain the exact certificate, schedule, marking and special conditions.
CircuitTwo-wire 4–20 mA with approved associated apparatusCheck voltage/current/power and cable capacitance/inductance against control documents.
Wet constructionQualified steel / titanium, compatible seals and oil-duty cableNo material option automatically inherits another model certificate.
Release documentsExact supplied model, certificate holder and installation drawingOwn SLV enquiry code is not the certified marking; IECEx/ATEX/UL/CSA are not interchangeable.

Locate ordinary indicators and controllers in the appropriate safe location; assess every component connected to the circuit.

Intrinsic safety needs the full loop assessed, not just a low-voltage supply or isolated barrier.

Leachate can combine corrosion and hazardous gases: obtain both process chemistry and area requirements.

Selection brief, not an issued manufacturing drawing, serial calibration certificate or blanket product approval. Confirm the exact release documents with the quotation.

INDEPENDENT TECHNICAL REFERENCES

Read the reference alongside its limits.

Independent reference: MicroSensor publishes model-specific approval information. Such evidence applies to the named equipment and conditions; it does not transfer to an SLV enquiry code or establish approval for a different circuit.

Third-party names identify independent sources. No affiliation, supplied-equipment approval or performance equivalence is claimed. Reviewed 17 November 2026.

READ THE INSTALLATION BEFORE THE SIGNAL

Keep a dry atmospheric reference and a stable sensor datum.

A fixed probe reads the liquid column above its diaphragm. Cable length covers the physical route to a dry termination. Neither a pipe-size label nor an image establishes the assembly dimensions.

Download installation & loop-load worksheet ↓
Intrinsic-safety circuit review concept, not an approved control drawing
Original installation concept. Two-wire loop example; digital interfaces and approved barrier circuits require their own drawings. Verify wiring, load and installation details against the configured assembly.

CONFIGURE YOUR PROBE & TERMINATION

One complete specification.
One clear quote request.

Set liquid head, density, signal and the installed cable route. The configuration code carries these choices into your engineering request.

ENQUIRY CONFIGURATION CODEComplete the measuring range
Indicative allowance per probe kit$84Probe, freight and tax excluded. Length prices apply to a matched base assembly; no generic first-5m FEP upgrade is free.

This code requests a configuration; the written quotation defines released dimensions, materials, approvals and availability.

Include this configuration in my RFQ ↗
Engineering accessories — indicative per probe kit

Bellows and desiccant options need a compatible compensation/vent design. Surge ratings, clamp load and controller functions are confirmed for the selected assembly.

START WITH YOUR INSTALLATION

Four operating environments, four different selection decisions.

Chemical dosing tanks →

Specify chemical submersible probes from concentration, temperature, complete wetted materials and actual liquid density.

Generator fuel tanks →

Define low-head diesel tank measurement with fuel blend, usable level, cable route, area classification and generator input.

Groundwater & telemetry →

Plan groundwater pressure span, deployment cable, surveyed datum and low-power logger integration for borehole networks.

Lift stations & CSO →

Select a wastewater hydrostatic probe around rags, grease, turbulence, cleaning access, vent protection and pump-control acceptance.

KEEP THE WHOLE LOOP IN VIEW

From probe selection to dry cable termination.

Before you specify SLV-EX

Is this a released stock model?

SLV-EX identifies an enquiry configuration family. Ask for the exact configured datasheet, materials, drawing and calibration acceptance criteria before placing an order.

Can I order cable length independently from range?

Yes, specify both independently. Cable must cover the installed route and service allowance; measuring range covers liquid head above the probe. The quote confirms maximum immersion and cable load.

START WITH THE INSTALLATION

Liquid. Depth. Cable. Signal.

Send these four inputs to start a configuration review.

Request an engineering quote ↗